Digital Blood Pressure Monitor Nissei DM 3000
This dual function blood pressure monitor can be used in automatic mode or can be used in oscillometric mode or auscultatory mode with digital column.designed to give professionals the option and to become a global standard.
Characteristics
Blood pressure measurement / Wrap cuff around upper part of arm to take a systolic and diastolic reading
Pulse rate measurements / Pulse rates can also be measured along with blood pressure
Easy operation allows measurement results to be obtained promptly
Automatic or manual measurement can be selected
Highly legible LCD display in the image of a mercury column
Records 7 measurement results and the average values (while taking automatic measurements)
AC adapter / Built-in Ni-MH rechargeable battery
Mercury-free blood pressure monitor with easy to read LCD display bar
As the production, exporting and importing of mercury will be prohibited by 2020, the DM-3000 incorporates a highly legible LCD bar display that extends vertically and is easy to use for clinical operators who are familiar with mercury manometers. With a white LED backlight, the bar display stands out attractively for easier viewing.
Equipped with two measurement methods: AUTO and MANUAL
Change between two methods of measurement with a single switch: easy to use automatic oscillometric(AUTO)and auscultatory (MANUAL) through the use of a stethoscope. The stethoscope measurement method has a pressure retention function for retaining systolic and diastolic blood pressure values, which have been determined, through the use of a SET/MEMORY button. Pre-pressurizing value can also be set using the selection dial.
Specifications
Model DM-3000
Measurement principle
Auto / ○ Oscillometric method Manual / ○ Auscultatory method
Indicator
Bar ( Digital column ) / ○ Display ( Digital Numeric ) / ○
Function to maintain inflation pressure ○
Pressure indication range 0-300mmHg
Measuring range
SYS / 50-250mmHg DIA / 40-180mmHg PUL / 40-160pul/min
Accuracy
Blood pressure / ±3 mmHg Pulse rate / ±5%
Inflation Automatic (air pump)
Exhaust Automatic (electric control valve) Quick exhaust / ○
Power supply AC adaptor / ○ Battery / Rechargeable battery
Power consumption 14W ( max. )
Memory 7 readings Average calculation / ○
Arm circumference 17-25cm ( S ) / Optional 23-32cm ( M ) / ○ 32-42cm ( L ) /
Operating environment +10℃ ~ +40℃ 15 ~ 85% RH or below ( noncondensing )
Storage environment -5℃ ~ +50℃ 85% RH or below ( noncondensing )
Dimensions ( W x H x D ) 135.7 x 206.0 x 275.9mm
Weight ( approx. ) without batteries 1260g