Set irrigator complete Enema Formesa
Medical device used to free the last stretch of the intestine from the feces and / or gas, with the introduction of a probe into the rectum and / or in the sigmoid. Its use is for diagnostic purposes, in proximity to a surgery, or just to a temporary difficulty to evacuate due to the presence of fecal impaction obstructive traumatizing, or in the event of constipation or other problems related to defecation. Can also be used in domestic
Equipped with anal cannula for enemas and vaginal irrigation cannula.
Accessories:
1 PVC bag with handle.
1 PVC transparent tube.
1 faucet with opening lever
1 connector.
1 short anal cannula.
1 long vaginal cannula.
Materials:
Bag: PVC (medical use)
Handle for bag: LDPE (low density polyethylene)
Transparent tube: PVC (medical use)
Connector: HDPE (high density polyethylene)
Anal cannula: HDPE (high density polyethylene)
Vaginal cannula: HDPE (high density polyethylene)
Faucet with opening lever – body: HDPE (high density polyethylene)
Faucet with opening lever – faucet: HDPE (high density polyethylene)
Features:
Bag dimensions: 105x105x215 mm + 5
Tube lenght 1350 + 20
Internal diameter of the tube 7,5 + 0,1
Esternal diameter of the tube 10,5 + 0,1
Coating:
Thickness 300 microns + 15
Width tension: length 215 + 10 Kg/cm2
Welding:
It resists static force of 100N (Newton) for 100 seconds.
Dispersion:The cap and its closing avoid water leakage.
Capacity:About 2 liters.
Assembling the device before use
Before performing any installation of the device follow the steps in the
Before performing any installation of the device, run a cleaning and sanitizing as described in "preventive checks before use" and if deemed necessary, perform a sterilization of parts in contact with the user (cannulas).Insert the fitting into the bottom of the bag, and screw it tight (no tools required).
In order to carry out the assembly, work in the following way:
Insert the transparent tube on the fitting, making sure that the same tube arrives to the stop of the door rubber,
Plug the other end of the transparent tube on the rubber door on the faucet with lever.
The stroke of insertion of the tube on the tap must be such as to ensure the subsequent liquid‐tight seal therapeutic that you will use and at the same time is useful to prevent slippage during manual operation, hang the bag in a suitable position and vertically, using the handle supplied; the support used must ensure a solid anchor in a position to avoid any contamination, or incidental introductions of liquid / foreign material inside the bag. The height positioning of the bag causes the water pressure within the tube; ask the doctor how high it should be placed the bag.
close the tap using the lever (the closing position is detectable with the orientation at 90 ° of the lever than the liquid flow),
tighten to the tap, one of the two tubes supplied (depending on usage).
Now the device is ready for use.
Preventive checks before use
Make sure before unpacking that the same is intact. If you think that there are some missing parts and / or damaged,
DO NOT USE IT, but refer to the person who sold the device.
For any specific questions please always contact your pharmacist / doctor of confidence.
BEFORE ANY USE, ALWAYS make sure that all the constituent parts of the device:
are intact and not damaged (for examlple the presence of cracks, bruises or lacerations),
they have not changed color or the colors were nonuniform, not have surface mold, etc.,
verify that any odors do not come from the bag inside and/or other components
in one of these cases DO NOT USE and REPLACE IMMEDIATELY.
Cleaning mode
Before using the device for the FIRST TIME and NEXT, manually remove all the parts and perform a wash using warm water and mild soap and then disinfect it well; The cannulas can be sterilized by gamma rays also with hot and with ethylene oxide.
For the appropriate sanitize method, manually remove all constituent parts of the device and consult your pharmacist/trusted Doctor, keeping in mind the composition of the various materials indicated in the specifications.
Do not use cleaning brushes, but only soft sponges so as not to scratch the surface.
Do not use alcohol, solvents or acids to clean the surfaces of the device.
Storage and Preservation
The medical device is supplied with the FOR.ME.SA. standard packaging which guarantees the proper storage.
To maintain the proper storage over the time, it is recommended to always use the original packaging together with a dry environment, not in direct contact with the heat radiating sources, protected from dust and harmful materials and outside of the reach of children.
Do not stack heavy parts on the device, do not submit the same to mechanical stress.
Do not store the device if some parts are damp and / or wet.
Improper uses
Some unauthorized use and then PROHIBITED of the device:Utilizzare a contatto con parti lese del corpo umano.
Use for temporary use over 60 minutes.
Used for irrigation different from those vaginal or rectal.
Introducing into the device substances which are not liquid and with a viscosity different from that of water. Use in conjunction with or as part of other medical devices.
Use with liquids with a temperature above 35 ° C.
Amend or alter the constituent parts and / or characteristics.
Use without having heard the opinion of a doctor.
Abuse.